位于河流和足球场之间的地块,在一个宽阔的环境中,Empalot区的MG3地块在城市构成系统中扮演着领导者的角色,为该项目提供了一个真正的大都市维度。这个 "景观建筑 "由一个垂直和一个水平的体量组成,相互滑动,与周围的体量相呼应,容纳了90个销售住房单元和20个社会住房单元。With a plot located between the river and a football field, in a wide-open environment, the MG3 lot of Empalot district acts as a leader in the urban composition system and offers a real metropolitan dimension to the project. Composed of a vertical and a horizontal volume sliding against each other and recalling the surrounding volumetrics, this «landscape building» hosts 90 housing units for sale and 20 social housing units.
这些住宅从一个房间到五个房间不等,在垂直建筑中被安排在12层,在水平建筑中被安排在5层。底层是一个会所,包括更衣室和一个可从足球场进入的公共房间,以及两个为残疾儿童服务的 "奥克西塔尼复原力 "协会的场所。地下两层还设有私人停车场,可从建筑的背面进入。The dwellings, ranging from one room to five-room, are arranged on 12 floors in the vertical building, and on 5 floors in the horizontal one. On the ground floor are a clubhouse containing the changing rooms and a common room accessible from the football field, and two premises for the “Resilience Occitanie” association dedicated to children with disabilities. Two basement levels also host private parking reachable from the backside of the building.两座建筑的滑动布局产生了两个大型的绿色户外空间,一个是建筑的主入口大厅,由一个大型景观门廊保护,另一个是通往建筑后面的楼梯间。The sliding layout of the two buildings generates two large green outdoor spaces, one hosting the main entrance hall of the building protected by a large landscaped porch, and the other giving access to the stairwells at the back of the building.阳台和遮阳板。由于主立面朝南,与一个足球场接壤,必须考虑如何保证所有公寓的夏季舒适度。这就是为什么建立了一个双重装置,结合大型金属遮阳板,沿着南面和西面的外墙延伸出2米宽的长阳台,并创造出真正的户外房间。Balconies and shades. With a south-facing main facade bordering a football field, it was essential to think about how to guarantee summer comfort to all apartments. That is why a double device has been set up, combining large metal sun protections, extending 2 meters wide long balconies all along the South and West facades, and creating real outdoor rooms in addition.在最后几层,只有一个覆盖整个阳台宽度的遮阳板像凉棚一样保护着居民。作为树叶的作用,这些遮阳物被认为和设计为提供类似于在一个阳光明媚的下午被树木覆盖的舒适感。在北区,简单的阳台,在最后一层有遮阳物的保护,也为最小类型的住房提供了一个户外空间。At the last levels, only a shade covering the entire width of the balconies protects the inhabitants like a pergola. Acting as foliage, these shades have been thought of and designed to provide similar comfort to that offered by the cover of a tree on a sunny afternoon. On the Northside, simple balconies, protected by a shade on the last level, also offer an outdoor space for the smallest typologies of housing.住房。 在里面,凉亭里有很多类型的住房,它们都受益于长长的阳台和对南方和西方的阳光保护。草原建筑的5层楼里也有同样的住房布局,都是交叉或双层的,并且总是有长长的阳台。在最后一层,一个巨大的景观和种植的露台沿着建筑的整个长度进行。大楼的所有居民都可以进入,它提供了一个大的户外空间,上面有一个木制的平台,一个日光浴室和一个儿童涉水池。Housing. Inside, the belvedere hosts large typologies of housing which all benefit from long balconies and sun protection to the South and West. The prairie building hosts the same layout of housing on its 5 floors, all crossing or double-oriented, and always accompanied by long balconies. On the last level, a huge landscaped and planted terrace takes place along the entire length of the building. Accessible to all the inhabitants of the building, it offers a large outdoor space covered with a wooden deck, a solarium, and a wading pool for children.建筑师:CoBe Architecture & Paysage
本资料声明:
1.本文为建筑设计技术分析,仅供欣赏学习。
2.本资料为要约邀请,不视为要约,所有政府、政策信息均来源于官方披露信息,具体以实物、政府主管部门批准文件及买卖双方签订的商品房买卖合同约定为准。如有变化恕不另行通知。
3.因编辑需要,文字和图片无必然联系,仅供读者参考;
合作、宣传、投稿
联系微信:soujianzhu006
推荐一个
专业的地产+建筑平台
每天都有新内容
扫描二维码关注
微信公众号“搜建筑”(ID:sjz9999)