竞赛类型 | 概念项目(无报名费)
Competition Type | Concept Project (Without Entry Fee)
项目功能 | 酒店建筑
Project Functions | Hotel Building
竞赛地点 | 贵州省,黔南州
Competition Site | Guizhou Province, Buyi and Miao Autonomous Prefecture of QianNan
参赛资格 | 无资格限制
Eligibility | No Qualification Restrictions
报名截止 | 2023年10月10日
Closing Date for Entries | October 10, 2023
提交截止 | 2023年10月31日
Submission Deadline | October 31, 2023
竞赛背景 /Competition Background
本项目位于中国贵州省黔南州州府都匀市,已加盟洲际酒店管理集团。现面向全球征集酒店创意设计概念方案,旨在打造富有创意和设计感的酒店,以提升自身的竞争力,适应行业发展的趋势。
The project is located in Duyun City, the state capital of the Buyi and Miao Autonomous Prefecture of QianNan, Guizhou Province, China, and has joined InterContinental Hotel Management Group. We are currently collecting the schemes of creative hotel design concept from around the world, with the aim of creating hotels with creativity and a sense of design to enhance their competitiveness and accommodate the tendency of industrial development.
本次竞赛的目标是通过酒店建筑的设计,实现一个在建筑创意设计方面脱颖而出、为客人提供独特体验的酒店的创新设计解决方案。
The target of this competition is to achieve an innovative design solution for a hotel that stands out from the crowd in terms of creative architectural design and provides guests with a unique experience by means of the design of the hotel building.
项目概况/ Project Overview
都匀,简称“匀”,市人口52.82万,有33个民族,少数民族占全州人口的68.5%,距贵阳市区不足78公里,周边旅游资源丰富,在市辖区范围内有秦汉影视城、绿博园、茶博园、斗蓬山、石板街等大小景区。
Duyun, or "Yun" for short, has a city population of 528,200, 33 ethnic groups. Ethnic minorities account for 68.5 percent of the entire prefecture's population. It is less than 78 kilometers from downtown Guiyang. The peripheral areas are rich in tourism resources. Within the municipal limits, there are several scenic spots, both large and small, such as Qin and Han Duyun Studio City, Green Expo Park, Tea Expo Park, Cloak Hill and Shiban Street.
占地面积:8023平方米
Floor area: 8,023 square meters
容积率:3.43
Plot ratio: 3.43
高度限制:100m
Height restriction: 100m
建筑面积:地下约7000平方米,地上约15000-18000平方米
Area of Structure: about 7,000 square meters underground and 15,000-18,000 square meters above ground.
主办方/ Sponsor
洲际智选假日中国贵州都匀店
Holiday Inn Express Guizhou Duyun Store in China of the InterContinental Hotels Group
参赛资格 / Eligibility
参与的最低合格年龄为18岁。比赛在全球范围内对任何学科的设计师开放,所有学生,专业人士及其设计单位都可以参加比赛。
The minimum eligible age for participation is 18 years old. The competition is open worldwide to designers of any discipline, and all students, professionals and their design units can participate.
评委 / Jury
洲际智选假日中国贵州都匀店专家委员会
Expert Committee of Holiday Inn Express Guizhou Duyun Store in China of the InterContinental Hotels Group
日程安排 / Competition Schedule
开始报名时间:2023年9月26日
Registration time: September 26, 2023
报名截止时间:2023年10月10日
Registration deadline: October 10, 2023
投稿截止时间:2023年10月31日
Submission deadline: October 31, 2023
获奖结果公布:2023年11月20日
Announcement of award results: November 20, 2023
奖项设置 / Awards Setting
冠军:6,000 美元;(约43873人民币)
Champion: $6,000; (approximately RMB 43,873)
现金+精制奖杯和证书+相关项目深化设计优先权
Cash + Refined Trophies and Certificates + Relevant Projects Deepening Design Priority
亚军:1,400美元;(约10237人民币)
Silver medal winner: $1,400; (approximately RMB 10,237)
现金+精制奖杯和证书+相关项目深化设计优先权
Cash + Refined Trophies and Certificates + Relevant Projects Deepening Design Priority
季军:600美元;(约4387人民币)
Third winner: $600; (approximately RMB 4,387)
现金+精制奖杯和证书+相关项目深化设计优先权
Cash + Refined Trophies and Certificates + Relevant Projects Deepening Design Priority
最受欢迎奖(10名):100美元;(约731人民币)
Most Popular Award (10 winners): $100; (approximately RMB 731)
现金+精制奖杯和证书
Cash + Refined Trophies and Certificates
作品要求/ Work Requirements
突破传统星级酒店及商务酒店的外观,不局限于常规形态的塔楼及裙楼的组合形式,在满足落地性的条件下充分发挥想象力,打造充满吸引力、能自带流量的地标性消费目的地。
Breaking the appearance of traditional starred and commercial hotels, it does not confine itself to the conventional combined form of tower and podium buildings, giving full play to the imagination in conditions that meet floorability, and creating a landmark consumer destination that is full of attraction and can bring its own traffic.
深掘利用项目与外界客观因素的联系,深掘利用项目与当代Z世代人群消费的关联,深掘项目内业态与设计的联系。
Dig deeper into the relation between utilization projects and external objective factors, dig deeper into the relevance of utilization projects to the consumption of contemporary Gen Z people, and dig deeper into the affiliation between business formats and design within projects.
联系方式/Contact Information
邮箱:Vihaaaaaafox@mail.com
E-mail: Vihaaaaaafox@mail.com
联系电话:17381591383
Contact Number: 17381591383